Number:YJ-180 Name: YJ-180 Full Automatic biochemistry analyzer Description:1,Newest model,perfect designing. 2,Mainframe of the computer with software installed along with analyzer,all test items and parameters can be set well before delivery. 3,Two persons can be trained fr...

High End Full Automatic biochemistry analyzer


Specification:

  Throughput constant 180 T/h or 300T/h,best for middle or small size hospital
  Closed integrated photovoltaic systems, no mechanical parts,maintenance free
  Minimum reaction volume is 150ul,cost saving
  Discrete,random access,automatic
  Random choice of method, the real discrete automatic chemistry analyzer
  This automatic chemistry analyzers have gained a lot of national patents during the researching.
  

Analyze Unit

1.  Throughput: constant 180 T/h, 81 reaction cuvette positions,multi-channel testing together.
2.  Minimum reaction volume is 150μl, cost saving.
3. Determined by the sample sequence, inserted at any time emergency.
4.  Heating method: Direct thermal solid thermostat closed.

Optical Unit

1.  Closed integrated photovoltaic systems, no mechanical parts,maintenance free.
2. Light Source:Halogen-tungsten lamp;
3. Lifetime≥2000 h.
4. 8 Wavelength,support single or dual wavelength.

Reagent Unit

1.  60 reagent positions.
2.  Automatically detect the amount of reagent remaining, displayed in real time the remaining amount of reagent.
3.  15ml, 20ml, 30ml, 50ml or 70ml reagent bottle. Dead volume <1.0 ml.
4.  Support for single and double reagent, reagent completely open.
Internal barcode reader (option).

Sample Unit

1. 60 sample positions.
2.  Testing according setting,random access.
3.  Real time display of testing status.
4.  Internal barcode reader (option).

Reagent/Sample handing Unit

1. Intelligent liquid detection & collision protection (Red light: collision; Blue light: detection of the liquid).
2.  Reagent volume: 2 ~ 500μl,step by 1μl .
3.  Probe cleaning:automatically washing for both inside and outside,carry over0.1%.
4. Automatically dilute and retest.

Calibration and quality control Unit

1. Linear curve type:Single-point linear,two-point linear and multi-point linear.
2. Nonlinear curve type:Logit-4p,Logit-5p,polynomial,factor.
3.  Automatically use best calibration curve and standard.
4.  Quality control chart:L-J,Westgard TwinPlot,Cumulative.

Operation Unit 

1.  Operation system: Windows XP/Office 2000,interface is intuitive and operate it easily, arbitrary operating authority;No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
2. Can print the contents of any custom;Offers a variety of print formats.
3.  Help and operation guide on line in English.
4.  No restrictions on setting test parameters.
5. Unique password for user management,rational allocation of user rights.
6.  Real time display of testing status,the remaining amount of reagent,testing status ,reaction curve and the test progress.
7. Real time display of reaction plate temperature.
RS-232 standard interface,support for the hospital network, print reports remotely.
 

Others

1. Temperature:10-30 degree
2. Humidity:less than 70%.
3. Try to avoid strong light.
4.  Floor level up:less than 1/200.
5. Barometric:86.0kPa-106.0kPa.
6.  Power Supply:AC 220V±22V 50Hz±1 Hz.
7.  Water consumption:less than 6L/h.
8. Frequency:550 VA.
9.  Dimension:782mm×581mm×545mm
10. Weight:60kg
 

Test projects

1. ALT,AST,TP,ALB,TBIL,DBIL,ALP,r-GT,CHE,TBA,5-NT
2.  UREA,CR,UA,TCO2
3. CHOL,TG,HDL,LDL,ApoA,ApoB,LPa
4. AMY,LIP
5. GLU,GSP
6. CK,CK-MB,a-HBDH,LDH,MB

7. CRP,RF,ASO

Model

YJ-180

Analyze Unit

Throughput

Constant 180T/h (non-ISE)

Theory

Absorption spectrometry, transmission turbidimetry

Methodology

End-point \Fixed-time\Kinetic\Ion selective electrode

Test according set up, random access

Reaction plate

Contain 81 reaction cuvettes

Maximum reaction time

15 minutes

Minimum reaction volume

150 ul

Material of cuvettes

Special UV-transparent optical glass

Cuvettes use

Automatically cuvettes washing

Optical Unit

Light Source

Halogen-tungsten lamp

Photometer

Reversed optics

Wavelength

340nm-900nm wavelength option

Absorption

0-4 Abs

Reagent Unit

Reagent plate

60 reagent positions ,support for single and double reagent, reagent completely open

Reagent storage temperature

2~10 degree

Reagent bottle

15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml

Reagent volume

20-500 ul, step by 1.0 ul

Reagent/Sample Probe

Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.

Sample Unit

Sample plate

60 sample positions

Sample type

Human (animal) serum \plasma\urine etc.

Samples cup

Support one-off micro cups

Sample volume

2-100 ul, step by 0.1 ul

Sample/reagent probe

Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.

Temperature control Unit

Heating method

Direct thermal solid thermostat closed

Temperature equilibrium time

<3 minutes

Reaction temperature

37 ±0.1 degree

Temperature fluctuation

±0.1 degree

Operation Unit

Software

WindowsXP \2000

Database

SQL Server

Data Storage

Automatic store & copy; No time and volume limit; Lifetime preservation

Print format

Can be set up, offer several standard format

Calibration mode

Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard

Quality control methods :

Real time, within day & between day

Quality control diagram

L-J \cumulative\twin plot

Status display

Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray

Adjustment

Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages         

Setting

Operation permission setting, Item setting, cross pollution setting, cuvette blank setting

Others

Water consumption : < 6L/h

Power Supply :AC 220V±22V 50Hz±1Hz

Frequency :Maximum 600VA

Dimension :782mm×581mm×545mm

Net Weight : 60kg

Accessory :Software

 

Note:We provides you with 12-24 months free repair guarantee for main unit, 12 months free repair guarantee for probe and 6 months free repair guarantee for the optional parts respectively.More information for our products and service,please turn to our official website or contact us directly.

 