Number:YJ-2000 Name:YJ-2000 Cassette Steam Autoclave Description:Quick sterilization for small type medical appliances used in detal clinic,E.N.T and gynaecoloy departments....

Features:

The shortest sterilization cycle only needs 6-7 minutes. Compared with the autoclave with a longer sterilization cycle, this quicker autoclave prolongs the life time of the medical appliances relatively, because the cycle time of the sterilized appliances exposed to the high temperature is less.

Three press buttons for different sterilization programs, the time and temperature of sterilization can be set freely according to the user’s needs.

Under the circumstances of unqualified water and water shortage in the tank, it gives an alarm signal and flashes on the display. for the low temperature and the low pressure during the sterilization process, it will stop the sterilization cycle automatically, the error information is displayed and printed at the same time.

Small dimension, light weight, wide ambient working condition, easy to operate . the cassette is also a good medical appliance container for temporary deposit and carry.

 

Applications:

Quick sterilization for small type medical appliances used in detal clinic,E.N.T and gynaecoloy departments.

 

After sterilization program selected and start key pressed, the steam generator heats to an optimum temperature, then certain volume of distilled wateris pumped into the generator and immediately converted into steam, a wall of steam is injected into the steam courses through the cassette, the unclean and cold air stored in the cassette at the first beginning is wholly removed.

 

Sterilization chart                           Sterilization Cycle Comparsion

 

A  Air removal   B Warming up              AdvantagesShorter cycle time, higher effciency

C  Pressurizing   D Sterilizing

E  Venting

Press

Press button

Sterilization temperature

Sterilization time

Dryness time

Appliance

110-135

4-99

0-99

Package appliance

110-135

4-99

0-99

Nonmatal appliance

110-135

4-99

0-99

Operates easily

Chinese language operation

The sign matches the-printer, but real-time record antiseptic process

The card box’s be ultrathin wall design, causes the warming andthe radiation is quicker

0.22 micron living thing filter

Machine dimensions                 

570*415*170mm

Cassette size(external)            

390*196*40mm

Cassette size(internal)            

280*180*38mm

Chamber volume                         

1.8L

Reservoir volume                       

3.4L

Electrical rating                  
                             

AC220V±10%

50Hz±1Hz 6 A Max 1.3kVA

Steam temperature                    
                                   

110-135℃(Selectable)